  HOME     ABOUT US     PRODUCTS     SERVICE / SUPPORT     CONTACT US
     
Low Frequency Online UPS TC10K-120K
 
Three phase in, one phase out
Microprocessor control
100% unbalance protection design
True on-line double conversion design providing all protection design
Isolated output
IGBT inverter design
Wide Input voltage windows
Pure sine wave output with less than 3%THD
Expandable battery run time
Generator compatible
Cold start
Sine wave pulse width modulation
Overload, on-line, battery status LED/LCD
Advanced Battery Management
Automatic charging in UPS off mode
Load/Battery power meter display
Smart RS-232 communication port
Optional SNMP card
 
TECHNICAL SPECIFICATION
MODEL TC10K TC15K TC20K TC30K TC40K TC60K TC80K TC100K TC120K
Capacity 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA
Power 8KW 12KW 16KW 24KW 32KW 48KW 64KW 80KW 96KW
Power Factor 0.8
Input  Phase 3 phase 4 wire and ground
 Voltage Range 380V20%(3 phase), phase voltage 220V
 Frequency Range 45 65Hz
 Rectifier 3 phase 6 pulses, 12 pulses is optional
Output  Phase 3 phase 4 wire and ground
 Wave form Pure sine wave
 Crest Factor 3:01
 Rated voltage 380/400/415V optiona+ -1% for static load, 5% forfluctuant load
 Phase voltage setting 200 - 244VAC, pls confirm when order
 Transient response +/-5%, 10ms
 Frequency 50 / 60 Hz + / - 0.05%
 Total harmonic   distortion < 3%(linear load, < 5%( nonlinear load)
 Short circuit current Short current for 0.1s (200% current)
 Overload capacity Overload 125% for 10 Mins, 125%-150% for 1min .automatically resume when load become normal
Battery  Battery Maintenance free lead-acid cell
 DC Voltage 384VDC 396VDC
 Max Charge Current 6-30A adjustable
Bypass  Type Static state + manual maintenance bypass
 Input Phase 3 phase 4 wire and ground
 Input voltage range 15% - 25% (the front control panel selectable)
 Transfer time Inverter / bypass transfer switch time(Overload): 0ms inverter / bypass transfer switch time (fault inverter) 1ms
Efficiency  Whole unit >80%
   Inverter 91 91 92 92 93 93 95 95 95
 Remote signaling Dry contact (battery low, battery discharging, bypass/ fault); output 12Vdc/80mA,Optional parts
 Communication interface RS232 ( SNMP , modem optional )
 Running temperature 0-40 degree Celsius
 Relative Humidity Less than 95% (without condensing)
 Noise at 1 M less than 60 dB
 Degree of protection IP20
 Applicable Standards EN50091-1-EMC EN50091-2liv.A
 Product size(mm) 780*580*1170 1000*660*1450 1200*900*1820
 product weight(Kg) 180 280 380 440 520 670 690 790 790
 Package size(mm) 945*745*1395 1135*810*1755 1450*1110*1880
 Package weight(Kg) 200 300 400 460 550 700 750 850 850
 